Example: bankruptcy

RFID Specifications Technical Data

Technical DataRFID SpecificationsBulletin Number 56 RFOur Bulletin 56RF High-frequency Radio Frequency Identification (RFID) system is ideal to track and document products as they move through the manufacturing process in light-duty industrial applications. The RFID system tags and transceivers are designed to the ISO 15693 open standard for high of Changes2 High-frequency EtherNet/IP Interface Block3 Transceivers18 mm and 30 mm Cylindrical Transceiver9 Square 40 x 40 mm Transceiver12 Rectangular 80 x 90 mm Transceiver14 Status Indicator Illumination Pattern16 Transceiver Cordsets and Patchcords16 Connector Pinout16 TagsDisc Tag ICODE SLI, SLIx.

Rockwell Automation Publication 56RF-TD001D-EN-P - December 2018 5 High-frequency EtherNet/IP Interface Block Table 6 - General Specifications Attribute 56RF-IN …

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of RFID Specifications Technical Data

1 Technical DataRFID SpecificationsBulletin Number 56 RFOur Bulletin 56RF High-frequency Radio Frequency Identification (RFID) system is ideal to track and document products as they move through the manufacturing process in light-duty industrial applications. The RFID system tags and transceivers are designed to the ISO 15693 open standard for high of Changes2 High-frequency EtherNet/IP Interface Block3 Transceivers18 mm and 30 mm Cylindrical Transceiver9 Square 40 x 40 mm Transceiver12 Rectangular 80 x 90 mm Transceiver14 Status Indicator Illumination Pattern16 Transceiver Cordsets and Patchcords16 Connector Pinout16 TagsDisc Tag ICODE SLI, SLIx.

2 And SL2 Memory17 Disc Tag ICODE FRAM Memory21 Disc Tag ICODE Large FRAM Memory23 Paper Tag ICODE SLIx and SLI Memory24 Proximity ISO Card ICODE SLI Memory27 High-temperature Tag Testing282 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID SpecificationsSummary of ChangesBulletin 57RF handheld interfaces have been removed from this publication due to product Automation Publication 56RF-TD001E-EN-P - July 20193 RFID Specifications High-frequency EtherNet/IP Interface BlockHigh-frequency EtherNet/IP Interface BlockThe EtherNet/IP interface block is designed to solve industrial high frequency MHz RFID applications that require networking or multiple read/write points.

3 Local status indicators allow for quick visual diagnosis of module status, network status, I/O status, and power interface block can have up to two transceivers and two general I/O devices, which allows the RFID system to be easily integrated into an existing architecture. This configuration also allows the RFID system to respond to sensor input and vice versa. For example, a sensor can detect the presence of an object and send a signal to the transceiver to read the RFID high frequency MHz RFID system is also highly configurable and expandable. The transceivers can be mounted up to m (300 ft) away from the interface blocks.

4 The EtherNet/IP ports are configured as an embedded switch with Device Level Ring (DLR), which allows multiple interface blocks to be connected in star, tree, linear, and ring topologies. The RFID system is ISO 15693 compliant and compatible with tags of many different styles and SelectionTable 1 - TransceiverInterface Port(1)(1) Configured as embedded switch. Supports star, tree, linear, and ring transceiver1156RF-IN-IPS122 transceivers1156RF-IN-IPD222 transceivers2 56RF-IN-IPD22 ATable 2 - Interface Block CablesInterfaceConnector StyleConnector TypeNo. of PinsShieldingWire Size (AWG)Cat.

5 Micro (M12) patchcordStraight female to straight male4 Shielded22889D-F5 FCDM-Jx(1)(1) Replace x with 0M3 [ m ( in.)], 1 [1 m ( ft], 2 [2 m ( ft)], 5 [5 m ( ft)], or 10 [10 m (33 ft)] for standard cable Micro (M12) cordsetStraight female889D-F5FC-Jx(2)(2) Replace x with 2 [2 m ( ft)], 5 [5 m ( ft)], or 10 [10 m (33 ft)] for standard cable male889D-M5FC-Jx(2)M12 terminal chamberStraight female male871A-TS5-DM1 Auxiliary powerDC Micro (M12) patchcordStraight female to straight male4 Unshielded22889D-F4 ACDM-x(1)DC Micro (M12) cordsetStraight female889D-F4AC-x(2)Straight male889D-M4AC-x(2))

6 M12 terminal chamberStraight female 871A-TS4-DStraight male871A-TS4-DMEtherNet/IPM12 D-code patchcordStraight male to straight male4 Shielded261585D-M4 UBDM-x(3)(3) Replace x with OM3 [ m ( in.)], OM6 [ m ( in.)], 1 [1 m ( ft)], 2 [2 m ( ft)], 5 [5 m ( ft)], 10 [10 m (33 ft)], 15 [15 m (49 ft)], and increments of 5 m ( ft) up to 75 m (246 ft).Straight male to right angle male1585D-M4 UBDE-x(3)Right angle male to right angle male1585D-E4 UBDE-x(3)Straight male to straight maleUnshielded241585D-M4 TBDM-x(3)Straight male to right angle male1585D-M4 TBDE-x(3)Right angle male to right angle male1585D-E4 TBDE-x(3)

7 4 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications High-frequency EtherNet/IP Interface BlockSpecificationsTable 3 - Input Table 4 - OutputTable 5 - RFID SpecificationsAttribute56RF-IN-IPS12, 56RF-IN-IPD22, and 56RF-IN-IPD22 ANumber of transceiver inputs2 56RF-IN-IPD22 and 56RF-IN-IPD22A1 56RF-IN-IPS12 Number of standard inputs2 56RF-IN-IPD22A1 56RF-IN-IPD22 and 56RF-IN-IPS12 Standard input typeSink, 24V DCVoltage, off-state input, max5V DCVoltage, on-state input, max30V DCVoltage, on-state input, nom24V DCVoltage, on-state input, min11V DCCurrent, off-state input, mA @ 5V DCCurrent, on-state input, max5 mA @ 30V DCVoltage, sensor source, max30V DCVoltage, sensor source, min10V DCInput delay timeON to OFFOFF to <Symbol>m<Symbol>sIsolation voltage50V (continuous)

8 , basic insulation type, inputs and sensor power to networkNo isolation between individual Inputs or between network channels Type tested at 707V DC for 60 sAttribute56RF-IN-IPS12 and 56RF-IN-IPD22 Number of standard outputs1 Standard output typeSource, 24V DCVoltage drop, on-state output, DCVoltage off-peak blocking, min30V DCVoltage, on-state output, max30V DCVoltage, on-state output, min11V DCVoltage, on-state output, nom24V DCCurrent on-state output, ALeakage current, off-state output, max50 <Symbol>m<Symbol>ASurge current per output, A for 10 ms, repeatable every 2 sIsolation voltage50V (continuous), basic insulation type, outputs, and output power to networkNo isolation between individual outputs or between outputs and output power or between network channelsType tested at 707V DC for 60 sAttribute56RF-IN-IPS12 and 56RF-IN-IPD22 Voltage24V DC ( +10%)Output current per RFID port, max100 mA @ 24V DCRockwell Automation Publication 56RF-TD001E-EN-P - July 20195 RFID Specifications High-frequency EtherNet/IP Interface BlockTable 6 - General SpecificationsAttribute56RF-IN-IPS12, 56RF-IN-IPD22, and 56RF-IN-IPD22 AVoltage, auxiliary power(1)

9 (1) Intended for limited voltage power, limited current DC ( +10%)Auxiliary current per module, max(2)(2) A listed or recognized 4 A fuse must be installed on the line side of the AOutput current per RFID transceiver port, max100 mA @ 24V DCCurrent for output device power per I/O port, A @ 30 VCurrent for input device power per I/O port, max5 mA @ 30 VCommunication rateEtherNet/IP10/100 MbpsFull or half-duplex100 meter per segmentStatus indicatorsModule Status - red/greenNetwork Status - red/greenLink Status - green/yellowAuxiliary Power - greenI/O Status Indicator - yellowDimensions (H x W x D), approx179 x 37 x mm ( x x in.)

10 Weight, kg ( lb)Enclosure type ratingIP67 and IP69 KWiring category(3)(3) Use this conductor category information for planning conductor routing. See publication , Industrial Automation Wiring and Grounding - on signal ports1 - on power ports1 - on communication ports6 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications High-frequency EtherNet/IP Interface BlockTable 7 - Environmental SpecificationsAttribute56RF-IN-IPS12, 56RF-IN-IPD22, and 56RF-IN-IPD22 ATemperature, operatingIEC60068-2-1/2, Test Ad/BdCold: -20 C (-4 F)Dry Heat: 60 C (140 F)Gradient: 1 C ( F)/minDuration: hr with insulation testsTemperature, storageIEC60068-2-1/2, Test Ad/BdCold: -40 C (-40 F)Dry Heat: 85 C (185 F)Gradient.


Related search queries